External Wall Insulation

 

Rainwater pipes are removed during the works and short lengths of temporary pipe fixed and taken over the scaffold away from the wall. Replacement downpipes are fixed on completion by sleeved fixings through the EWI system.

An extra thickness of insulation boards may be fixed around openings to create a feature. The bands are meshed and rendered and can be given a contrasting colour and/or texture to the main wall areas.

HALF OF A TYPICAL PAIR OF SEMI-DETACHED HOUSES


Click on the icon to download this page in printable PDF format



get adobe acrobat











 
1.

Additional shaped pieces of mesh are bedded around all wall openings.

2.

Extra mechanical fixings are used around all wall openings at 300mm centres max.

3.

The chimney may be treated to match the finish on the main walls.

4.



102m polyester coated aluminium verge accessory with jointing collars at 2.5m centres. Range of sizes exist to suit varying insulation slab thickness.

5.









Undercill or overcill extenders can be supplied in 1.2 - 3.0mm thick polyester coated aluminium with matching push fit end caps for site fabrication.

Cill extenders may also be site measured by Thermaloc technical personnel and factory fabricated with one piece welded end caps. Cill details are also available in moulded GRP or extruded GRC sections.

6.


Insulation slabs overlap alternate courses and are mechanically fixed 150mm in from arris and every 300mm vertically.

7.







At party wall positions, the EWI system may be terminted using a full depth stop bead or an external angle bead. The render finish is returned for teh full depth of the system.
N.B. Where the adjoining property is also being treated, allow for fitting Thermaloc expansion joint/movement joint bead.


 
8.









Where possible, a reduced thickness of insulation slab may be returned at opening reveals and heads dependent on window or door frame thickness. External angles are reinforced with polyester coated galvanised steel or stainless steel angle beads.

Where frames are too small, mesh and render alone may be used. A contrasting colour may be used at reveals.

9.



1200mm x 600mm x thickness insulation slabs are fixed using selected fixings.
N.B. all fixings are chosen subject to site pull out testing.

10.



Mesh reinforcing fabric bedded into adhesive render coat and allowed to dry for a minimum of 12 hours, but not exceeding 24 hours, before render finishing coat is applied.

11.



All external building corners are reinforced with polyester coated galvanised steel or stainless steel angle beads to give maximum impact resistance.

12.



Trowel applied Wetherbuild dashing mortar is through coloured and can be dashed with a wide range of mineral aggregates, or finished with a special finish (see special coatings).

13.





The base of the system is reinforced by the use of a full depth bellcast bead in polyester coated galvanised steel or stainless steel and finished with a plastic nosing available in a limited range of colours. Line of base level is usually set at DPC level.

14.

Plinth below DPC level of the existing wall may be painted with Wetherbuild masonry paint.


  Thermaloc | Wetherbuild | Wetherbrick | GRP Canopies
  External Insulation | Renders & Components | Real Brick Slips | GRP Canopies | Colour Samples
Technical Support |
U-Value Request |Certification | Guarantees | Resources | Contact Us
site disclaimer © Thermaloc 2003-2004. All rights reserved.
  Part of Wetherby Building Systems.
 
site designed & maintained by Athena Visual Productions